{"id":83460,"date":"2018-02-20T23:50:30","date_gmt":"2018-02-20T23:50:30","guid":{"rendered":"https:\/\/writemyessayfree.com\/hydraulic-services-2"},"modified":"2017-08-18T08:12:05","modified_gmt":"2017-08-18T08:12:05","slug":"hydraulic-services-2","status":"publish","type":"post","link":"https:\/\/www.benedictsol.com\/blogs\/hydraulic-services-2\/","title":{"rendered":"HYDRAULIC SERVICES"},"content":{"rendered":"<p>HYDRAULIC SERVICES<br \/> The plans, elevations and section for a proposed fitness centre development are available on vUWS. They include six A3<br \/> sheets numbered DA-101; DA-102; DA-103; DA201; DA-202 and DA-301. The project is located in Rockhampton, on the<br \/> central coast Queensland.<br \/> Assume that each of the following is available:<br \/> Sewer: DN150 sewer located in the nature strip to the southern footpath of the road, with an assumed<br \/> invert level of RL 41.500. Sanitary drainage will connect to this main via a sewer boundary trap<br \/> (SBT) located within the property on the northern boundary. Design is required to upstream<br \/> side of SBT only.<br \/> Stormwater: Stormwater will discharge to a below-grade SDT in southern boundary carpark (see location<br \/> and plan dimensions on drawing) and then to the western kerb of the street. The gutter<br \/> discharge RL will need to be determined as part of the exercise. Use rainfall intensity data for<br \/> Rockhampton based on 20 minute duration (10 year ARI) and accept that Local Council<br \/> requires a design based on maximum 90L\/s\/Ha allowable runoff (i.e. your exercise is to<br \/> nominate the SDT depth based on inflow versus allowable outflow at the 20minute peak).<br \/> Potable water: DN100 main located in western footpath to the street, with invert at a constant 1.0m below<br \/> footpath. The supply authority can only guaranteed a pressure of 18mH and because it is in a<br \/> new growth area of the city, you need to install a surge tank as the mandatory design. You<br \/> must achieve 150kPa at the most disadvantaged outlet. Consider carefully the facilities and<br \/> determine overall capacity (mH and L\/s) for a pressure set serving the development from a<br \/> surge tank location that you will note on your drawings.<br \/> Assessment Criteria<br \/> Using your appreciation of hydraulics installations to all levels of the building (Under-floor, ground and first floors<br \/> and roof), determine the following noting that you will be assessed on the points in each section:<br \/> 1. Cold Water Supply System [40% of assignment 2]<br \/> Recommend a reticulation system. Provide a single line diagram of the system, indicating pressure zones,<br \/> loading units, select pipe sizes to limit velocity to acceptable limits and pressure sets requirements.<br \/> a). Single line diagram<br \/> ? Loading units [15% overall]<br \/> ? Pipe sizes [10% overall]<br \/> b). Pressure set capacity (in mH and Q) [15% overall including surge tank location]<br \/> 2. Roof Areas Drainage System [40% of assignment 2]<br \/> Design the stormwater drainage system. Provide a single line diagram showing the collection system, including<br \/> flow rates, pipe sizes and falls to detention tank, the location of which is at your discretion. Determine detention<br \/> tank capacity.<br \/> Page 2 of 3<br \/> a). Assumptions<br \/> ? Storm intensity calculations [20% overall]<br \/> b). OSD tank<br \/> ? Capacity calculations [20% overall]<br \/> 3. Sanitary Plumbing and Drainage System [20% of assignment 2]<br \/> Design the sanitary plumbing and sanitary drainage system, including sizing of pipe work from pans, urinals,<br \/> basins, showers and sinks. The single line diagram should extend to the connection with the authorities system,<br \/> including the desired invert levels where applicable.<br \/> a). Pipe work sizing<br \/> ? FU loadings [10% overall]<br \/> b). Single line diagram<br \/> ? Layout and pipe sizes [10% overall]<br \/> Standards<br \/> Criteria<br \/> Unsatisfactory<br \/> [Fail]<br \/> Satisfactory<br \/> [Pass]<br \/> Good<br \/> [Credit]<br \/> Very Good<br \/> [Distinction]<br \/> Excellent<br \/> [High<br \/> Distinction]<br \/> Marks<br \/> awarded<br \/> (maximum<br \/> 100 which<br \/> will be<br \/> multiplied by<br \/> 0.15)<br \/> &lt; 50 points 50 \u2013 64 points 65 \u2013 74 points 75 \u2013 84 points<br \/> 85 \u2013 100<br \/> points<br \/> Hydraulics<br \/> design<br \/> Very poor or no<br \/> assumptions<br \/> Diagrams<br \/> inadequate or<br \/> incomplete<br \/> Incomplete<br \/> schematic<br \/> Section(s) of<br \/> assignment<br \/> missing<br \/> Basic<br \/> assumptions<br \/> but needing<br \/> justification<br \/> Very basic<br \/> schematic<br \/> Little thought<br \/> in logistics<br \/> Adequate<br \/> assumptions<br \/> with capacity<br \/> to operate<br \/> effectively<br \/> Schematic<br \/> acceptable<br \/> All requests<br \/> included<br \/> Assumptions<br \/> fully inclusive<br \/> and detailing<br \/> sizes, grades,<br \/> venting etc.<br \/> Clear<br \/> evidence of<br \/> critical<br \/> thought in<br \/> logistics and<br \/> schematic<br \/> presentation<br \/> Professional<br \/> submission<br \/> encompassing<br \/> all<br \/> requirements<br \/> in a realistic<br \/> resolution<br \/> Learning Outcomes Addressed<br \/> ? Interpret building regulations<br \/> ? Regulatory knowledge<br \/> ? Communicate professionally within regulatory frameworks<br \/> ? Recognise environmental connections with built form<\/p>\n","protected":false},"excerpt":{"rendered":"<p>HYDRAULIC SERVICES The plans, elevations and section for a proposed fitness centre development are available on vUWS. They include six A3 sheets numbered DA-101; DA-102; DA-103; DA201; DA-202 and DA-301. The project is located in Rockhampton, on the central coast <a href=\"https:\/\/www.benedictsol.com\/blogs\/hydraulic-services-2\/\" class=\"read-more\">Read More &#8230;<\/a><\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[],"tags":[],"class_list":["post-83460","post","type-post","status-publish","format-standard","hentry"],"_links":{"self":[{"href":"https:\/\/www.benedictsol.com\/blogs\/wp-json\/wp\/v2\/posts\/83460","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.benedictsol.com\/blogs\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.benedictsol.com\/blogs\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.benedictsol.com\/blogs\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.benedictsol.com\/blogs\/wp-json\/wp\/v2\/comments?post=83460"}],"version-history":[{"count":0,"href":"https:\/\/www.benedictsol.com\/blogs\/wp-json\/wp\/v2\/posts\/83460\/revisions"}],"wp:attachment":[{"href":"https:\/\/www.benedictsol.com\/blogs\/wp-json\/wp\/v2\/media?parent=83460"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.benedictsol.com\/blogs\/wp-json\/wp\/v2\/categories?post=83460"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.benedictsol.com\/blogs\/wp-json\/wp\/v2\/tags?post=83460"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}